If a claim ever reaches a courtroom involving a bounce house injury, the plaintiff's expert will almost certainly cite ASTM F2374 within the first five minutes. In Michigan's recent Noble v. Friends & Family Funland, LLC (2026) decision, industry standards were explicitly treated as evidence of the standard of care — not negligence per se, but a benchmark the operator was measured against.
This post walks through what ASTM F2374 covers, how courts actually use it, and the specific operator obligations it imposes that many businesses overlook.
This is not legal advice. ASTM standards are copyrighted and must be purchased from ASTM International; this post summarizes the operator-facing scope only.
What ASTM F2374 is
ASTM F2374 is the Standard Practice for Design, Manufacture, Operation, and Maintenance of Inflatable Amusement Devices. It's published by ASTM International and is referenced — by name or by incorporation — in many state amusement-ride regulations and in operator certification programs like SIOTO.
The standard is updated periodically. The exact section numbers in this post are approximate; buy the current edition before you build operational procedures from it.
The standard covers roughly four areas relevant to a rental operator:
- Design and manufacture — materials, seams, blower attachment, anchor points. Mostly the manufacturer's problem; relevant to you when sourcing equipment.
- Installation and anchoring — number and spec of anchors, surface conditions, clear-space around the unit.
- Operation — attendant ratios, participant rules, wind limits, inspection cadence.
- Maintenance and record-keeping — logs, inspections, repair documentation, service life.
The operating obligations most operators miss
1. The 25 mph / manufacturer rating ceiling
ASTM F2374 requires shutdown and deflation when sustained wind reaches the manufacturer's rated maximum or 25 mph, whichever is lower. This is covered in detail in our Chapter 10 post on wind limits, but it bears repeating: this is a hard operating ceiling, not a recommendation.
2. The attendant requirement
The standard requires a trained attendant during operation. "Trained" is defined by the attendant's demonstrated knowledge of the operating rules, emergency procedures, and participant management. In practice this means:
- The attendant has been through a documented training program
- There's a signed training record
- The attendant is actually present and watching during operation
Drop-off rentals — where the operator delivers the unit and the renter supervises — complicate this. The standard contemplates a trained operator; a drop-off puts a non-trained person in the attendant chair. Your contract has to address this allocation of duties explicitly, and your insurance has to be comfortable with the exposure (many carriers are not — check before you offer drop-off).
3. Pre-operation inspection
The standard requires a documented inspection before each use day: anchors, blower, fabric, seams, access area, surface. Many operators do the inspection; few document it. The documentation is what matters in a claim. A one-page checklist, dated, signed, retained for the manufacturer-specified period (often three to seven years).
4. Participant rules
Height, weight, and age restrictions per manufacturer specification. Mixing adults and children, mixing age groups, barefoot-only rules, no shoes/jewelry/food — these aren't suggestions. The standard treats operator enforcement of participant rules as a core duty.
5. Clear-space
A clear zone around the inflatable, usually six feet, free of fences, trees, electrical lines, pavement edges. Your intake form has to collect enough information to verify this is achievable at the delivery site; your crew has to confirm it at setup.
How courts use the standard
Three patterns show up in case law:
Pattern 1: Standard of care baseline
The Noble v. Friends & Family Funland approach — the standard is evidence of what a reasonable operator does. Deviation from the standard is evidence of negligence, not conclusive proof. The operator can rebut with their own expert and specific facts.
Pattern 2: Negligence per se
A handful of state statutes incorporate ASTM standards by reference. In those states, operating outside the standard can be treated as negligence per se — the plaintiff doesn't have to prove the standard applied; the statute says it does.
Pattern 3: Industry custom as duty
Even where no statute applies, courts sometimes treat widely adopted industry standards as establishing a duty. ASTM F2374 is widely enough adopted — through state regulation, insurance underwriting, and operator certification — that this is a real risk.
The three documents every operator should have
1. Current ASTM F2374 copy
Buy it. Read it. It's a few hundred dollars and it's the specification against which you're measured.
2. Written safety program
Required by ASTM F2374 for operators; see our Chapter 12 post. This is the document that proves you've thought about compliance, trained your crew, and set procedures.
3. Documented training records
Each crew member has a signed training record showing which rules they were trained on, when, and by whom. Refresh annually.
The SIOTO question
The Safe Inflatable Operators Training Organization (SIOTO) is the only industry-wide certification program. SIOTO training is built around ASTM F2374 (and related ASTM standards for operation and attendants). Three things worth knowing:
- SIOTO certification is not legally required anywhere in the U.S., but some insurers and some venues require or prefer it.
- SIOTO refuses to accept businesses operating units sold for home use — their program is scoped to commercial equipment.
- SIOTO covers bounce houses, combos, and slides up to 16 feet. Larger units need other training.
If you're starting fresh, SIOTO plus a documented in-house training program is the strongest documentation story.
The one-sentence takeaway
ASTM F2374 is not optional reading. It's the specification your attorneys will quote at you in a bad deposition — and it's the specification that, done right, keeps the deposition from happening.
This is a distillation of Chapter 9 of the free Operator's Manual — [download the full PDF](/manual) for the full ASTM F2374 operator-facing summary, the SIOTO training comparison, and the integration of ASTM requirements into your written safety program.